Revision Date: A
p
r. 10, 2007
Renesas Microcomputer Development Environment System
SuperH Family / SH7200 Series
SH7260 Series
E10A-USB for SH7261 HS7261KCU01HE
Rev.3.00
SuperH Family E10A-USB Emulator
Additional Document for User’s Manual
Supplementary Information on Using the SH7201
and SH7261
REJ10J1274-0300
Vue de la page 0
1 2 3 4 5 6 ... 51 52

Résumé du contenu

Page 1 - Rev.3.00

Revision Date: Apr. 10, 2007Renesas Microcomputer Development Environment SystemSuperH™ Family / SH7200 Series SH7260 Series E10A-USB for SH

Page 2

4 5 mm2-5767004-2Target systemE10A-USB optional 38-pin user system interface cableH-UDI port connector (top view): Area to be kept free of other com

Page 3

5 AUDCKN.C.TCKGNDAU DATA 0GNDAU DATA 1GNDGNDGNDGNDGNDGNDGNDAU DATA 2AU DATA 3UVCCTMSGNDN.C.GND(GND)TDIGNDGNDGNDGNDGNDGNDGNDTDO12345678910111213141516

Page 4

6 Pin 1 markNotes: 1. Input to or output from the user system.2. The symbol (_) means that the signal is active-low.3. The emulator monitors the GND

Page 5 - Contents

7 N.C.N.C._ASEMD (GND)TCKN.C._AUDSYNCN.C.N.C.AUDATA0AUDATA1UVCC_AUDN.C.N.C.TMS_UCON (GND)N.C.AUDCKUVCCN.C.N.C._RESTDIH-UDI port connector (top view)U

Page 6

8 1.5 Recommended Circuit between the H-UDI Port Connector and the MCU 1.5.1 Recommended Circuit (36-Pin Type) Figure 1.5 shows a recommended circ

Page 7

9 When the circuit is connected as shown in figure 1.5, the switches of the emulator are set as SW2 = 1 and SW3 = 1. For details, refer to section 3.

Page 8

10 1.5.2 Recommended Circuit (14-Pin Type) Figure 1.6 shows a recommended circuit for connection between the H-UDI port connector (14 pins) and the

Page 9

11 When the circuit is connected as shown in figure 1.6, the switches of the emulator are set as SW2 = 1 and SW3 = 1. For details, refer to section 3

Page 10

12 1.5.3 Recommended Circuit (38-Pin Type) Figure 1.7 shows a recommended circuit for connection between the H-UDI and AUD port connectors (38 pins

Page 11 - (top view)

13 When the circuit is connected as shown in figure 1.7, the switches of the emulator are set as SW2 = 1 and SW3 = 1. For details, refer to section 3

Page 13

14 Note: When the emulator is used, the AUD trace mode is set without using AUDMD or _AUDRST. If those functions are enabled, do not set these pins

Page 14

15 Section 2 Software Specifications when Using the SH7201 or SH7261 2.1 Differences between the MCU and the Emulator 1. When the emulator system

Page 15

16 3. Low-Power States • When the emulator is used, the sleep state can be cleared with either the clearing function or with the [STOP] button, and

Page 16

17 Table 2.3 Stopping Time by Memory Access (Reference) Method Condition Stopping Time H-UDI read/write Reading of one longword for the internal

Page 17

18 8. Operation while Cache is Enabled When cache is enabled, the emulator operates as shown in table 2.4. Table 2.4 Operation while Cache is En

Page 18

19 9. Multiplexing the AUD Pins The AUD pin is multiplexed as shown in table 2.5. Table 2.5 Multiplexed Functions Function 1 Function 2 PF2/TCLK

Page 19

20 11. Loading Sessions Information in [JTAG clock] of the [Configuration] dialog box cannot be recovered by loading sessions. Thus the TCK value wi

Page 20

21 • CD-ROM When the emulator is in use, the CD-ROM decoder cannot be accessed in the module standby state. Clear the module standby state before ac

Page 21

22 When the emulator is used, note the following to avoid H-UDI read/write access: • Display of the toolchip on the C source ⎯ Disabling H-UDI re

Page 22

23 2.2 Specific Functions for the Emulator when Using the SH7201 or SH7261 2.2.1 Event Condition Functions The emulator is used to set event condit

Page 23

1. This document is provided for reference purposes only so that Renesas customers may select the appropriate Renesas products for their use.

Page 24

24 Table 2.9 Dialog Boxes for Setting Event Conditions Function Dialog Box Address Bus Condition (Address) Data Bus Condition (Data) Bus S

Page 25

25 Sequential Setting: Using the [Combination action (Sequential or PtoP)] dialog box specifies the sequential condition and the start or end of per

Page 26

26 Table 2.10 Conditions to Be Set (cont) Classification Item Description [Ch4, 5] list box Setting is disabled in this MCU. Don’t care [Don’

Page 27

27 Usage Example of Sequential Break Extension Setting: A tutorial program provided for the product is used as an example. For the tutorial program,

Page 28

28 Figure 2.1 [Source] Window at Execution Halted (Sequential Break) If the sequential condition or performance measurement start/end is set, con

Page 29

29 7. If the settings of the Event condition or the sequential conditions are changed during execution of the program, execution will be suspended

Page 30

30 Table 2.12 shows the type numbers that the AUD function can be used. Table 2.12 Type Number and AUD Function Type Number AUD Function HS0005KC

Page 31

31 To set the AUD trace acquisition mode, click the [Trace] window with the right mouse button and select [Setting] from the pop-up menu to display t

Page 32

32 When the AUD trace function is used, select the [AUD function] radio button in the [Trace type] group box of the [Trace mode] page. (a) Branch Tr

Page 33

33 Figure 2.3 [AUD Branch trace] Page (b) Window Trace Function Memory access in the specified range can be acquired by trace. Two memory ranges c

Page 35

34 [Setting Method] (i) Select the [Channel A] and [Channel B] check boxes in the [AUD function] group box of the [Trace mode] page. Each channel

Page 36

35 Note: When [M-Bus] or [I-Bus] is selected, the following bus cycles will be traced. • M-Bus: A bus cycle generated by the CPU is acquired. A bus

Page 37

36 7. If breaks occur immediately after executing non-delayed branch and TRAPA instructions and generating a branch due to exception or interrupt,

Page 38

37 in advance because a user stack is to be used. By default, use of a user stack is disabled. For details on the command, refer to the help file.

Page 39

38 (a) Specifying the measurement start/end conditions The measurement start/end conditions are specified by using Event Condition 1,2. The [Ch1,2,

Page 40

39 Note: When [Ch2 to Ch1 PA] or [Ch1 to Ch2 PA] is selected, to execute the user program, specify conditions set in Event Condition 2 and Event Con

Page 41

40 Table 2.15 Measurement Item Selected Name Option Disabled None Elapsed time AC (The number of execution cycles (Iφ) is set as the measuremen

Page 42

41 Notes: 1. In the non-realtime trace mode of the AUD trace, normal counting cannot be performed because the generation state of the stall or the

Page 44

SuperH™ Family E10A-USB EmulatorAdditional Document for User's ManualSupplementary Information on Using the SH7201 a

Page 45

iContents Section 1 Connecting the Emulator with the User System ...1 1.1 Components of the Emulator ...

Page 46

Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japanhttp://www.renesas.comRefer to

Page 48

SuperH™ Family E10A-USB Emulator Additional Document for User’s Manual Supplementary Information on Using the SH720

Page 50 - RENESAS SALES OFFICES

1 Section 1 Connecting the Emulator with the User System 1.1 Components of the Emulator The E10A-USB emulator supports the SH7201 and SH7261 (R5S7

Page 51

2 1.2 Connecting the Emulator with the User System To connect the E10A-USB emulator (hereinafter referred to as the emulator), the H-UDI port conne

Page 52 - Using the SH7201 and SH7261

3 1.3 Installing the H-UDI Port Connector on the User System Table 1.3 shows the recommended H-UDI port connectors for the emulator. Table 1.3 Re

Commentaires sur ces manuels