To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C
4 1.5 Recommended Circuit between the H-UDI Port Connector and the MPU 1.5.1 Recommended Circuit Figure 1.2 shows a recommended circuit between the
5 1TCKTMSRESETTDITDOTRSTGNDGNDGNDGNDGNDGND234567ASEMD891110121314TCKRESTMSTDOTDITRSTN.C.N.C.SH7618VccQ (3.3 V)VccQ (3.3 V)H-UDI port connector(14-pin
7 Section 2 Specifications of the SH7618 E10A Emulator’s Software 2.1 Differences between the SH7618 and the Emulator • When the emulator system
8 • Reset Signals The SH7618 reset signals are only valid during emulation started with clicking the GO or STEP-type button. If these signals are i
9 Do not use the UBC in the user program as it is used by the E10A emulator when [EML] is specified in the [UBC mode] list box in the [Configuration]
10 2.2 Specific Functions for the SH7618 E10A Emulator The SH7618 E10A emulator does not support the following function: • MMU-related functions (T
11 2.2.2 Break Condition Functions In addition to BREAKPOINT functions, the emulator has Break Condition functions. Three types of conditions can be
12 Table 2.5 lists the combinations of conditions that can be set under Break Condition 1, 2, 3. Table 2.5 Dialog Boxes for Setting Break Condition
13 Internal Trace Function: This function is activated by selecting the [Internal trace] radio button in the [Trace type] group box of the [Trace mo
Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang
14 6. When a BREAKPOINT is set to the slot instruction of a delayed branch instruction, the PC value becomes an illegal value. Accordingly, do not
SuperHTM Family E10A EmulatorAdditional Document for User's ManualSpecific Guide for the SH7618 E10A Emulator
1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 JapanSuperH™ Family E10A EmulatorREJ10B0077-0100HAdditional Document for User’s Manua
SuperH™ Family E10A EmulatorAdditional Document for User’s ManualUser’s Manual Rev.1.0 2003.12SH7618 E10A HS7618KCM02HERenesas Microcomputer Develo
Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and
i Contents Section 1 Connecting the Emulator with the User System...1 1.1 Components of the Emulator ...
ii
1 Section 1 Connecting the Emulator with the User System 1.1 Components of the Emulator The SH7618 E10A emulator supports the SH7618. Table 1.1 l
2 1.2 Connecting the E10A Emulator with the User System To connect the E10A emulator (hereinafter referred to as the emulator), the H-UDI port conne
3 Pin 1 markNotes: 1. Input to or output from the user system.2. The slash (/) means that the signal is active-low.3. The emulator monitors the GND s