Renesas H8/36014 Informations techniques

Naviguer en ligne ou télécharger Informations techniques pour Non Renesas H8/36014. Renesas H8/36014 Technical information Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 32
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas
Electronics Corporation took over all the business of both
companies.
Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Page 2

iPrefaceThank you for purchasing this user system interface cable (HS36014ECH61H) for the Renesas’soriginal microcomputer H8/36014 series.The HS36014E

Page 3 - User’s Manual

iiContentsSection 1 Configuration...1Section 2 Connection Proced

Page 4 - Cautions

1Section 1 ConfigurationCAUTIONUse an IC149-064-075-B51 socket (manufactured byYAMAICHI ELECTRONICS Co., Ltd.) for the FP-64Epackage IC socket on t

Page 5 - IMPORTANT INFORMATION

2Table 1 lists the HS36014ECH61H components. Please make sure you have all of thesecomponents when unpacking.Table 1 HS36014ECH61H ComponentsNo. Comp

Page 6 - DISCLAIMER

3Section 2 Connection Procedures2.1 Connecting User System Interface Cable to Emulator Station(H8/36014 Series)WARNINGObserve the precautions listed

Page 7

4Figure 2 Connecting User System Interface Cable to Emulator Station

Page 8 - SAFETY PAGE

52.2 Connecting User System Interface Cable to Expansion I/O Board(H8/36024 Series)WARNINGAlways switch OFF the user system and the emulatorproduct be

Page 9

6Cable body connectorUser system interface cableCTS screws (M3 x 6 mm)Expansion I/O board cableUSER INTERFACE CABLE6000 EMULATOE6000Figure 3 Connect

Page 10

72.3 Connecting User System Interface Cable to User SystemWARNINGAlways switch OFF the user system and the emulatorproduct before the USER SYSTEM INTE

Page 11 - Contents

82.3.3 Inserting Cable HeadCAUTIONCheck the location of pin 1 before inserting.Align pin 1 on the IC socket for an FP-64E package on the user system w

Page 12 - Section 1 Configuration

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Page 13

9Fasten the user system interface cable head to the IC socket for an FP-64E package on the usersystem with the four screws (M2 x 12 mm; with four flat

Page 14

102.3.5 Fastening Cable BodyConnect the cable body to the cable head.Figure 5 Fastening Cable Body

Page 15

112.4 Recommended Dimensions for User System Mount PadFigure 6 shows the recommended dimensions for the mount pad (footprint) for the user systemwith

Page 16

122.5 Dimensions for User System Interface Cable HeadThe dimensions for the user system interface cable head are shown in figure 7.Figure 7 Dimensio

Page 17 - Expansion I/O board cable

132.6 Resulting Dimensions after Connecting User System Interface CableThe resulting dimensions, after connecting the user system interface cable head

Page 18

14Section 3 Installing the MCU to the User SystemCAUTION1. Check the location of pin 1 before inserting.2. Use a Philips-type screwdriver whose head

Page 19 - 2.3.4 Fastening Cable Head

15Figure 9 Installing MCU to User System

Page 20

16Section 4 Verifying Operation1. When using the H8/36014 series E6000 emulator (HS3664EPI61H), turn on the emulatoraccording to the procedures desc

Page 21 - 2.3.5 Fastening Cable Body

17Figure 10 shows the system clock oscillator on the user system interface cable.Figure 10 System Clock Oscillator

Page 22

18Section 5 Notice1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cablehead before inserting the cable h

Page 23

H8/36014 Group, H8/36024 Group FP-64E User System Interface Cable for E6000 EmulatorUser’s ManualUser’s Manual Rev.2.0 2003.12HS36014ECH61H Renesas

Page 24

196. The P1 short connector is used for testing. Do not remove the inserted jumper pin.Figure 12 P1 Short Connector

Page 25

H8/36014 Group, H8/36024 Group FP-64E User System Interface Cable for E6000 Emulator User's ManualPublication Date: Rev.1.00, March 18, 2002

Page 26

1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 JapanH8/36014 Group, H8/36024 Group FP-64EUser System Interface Cable for E6000 Emula

Page 27

CautionsKeep safety first in your circuit designs!1. Renesas Technology Corp. puts the maximum effort into making semiconductor productsbetter and mor

Page 28

IIMPORTANT INFORMATIONREAD FIRST• READ this user's manual before using this user system interface cable.• KEEP the user's manual handy for f

Page 29 - Section 5 Notice

IILIMITED WARRANTY Renesas warrants its user system interface cables to be manufacturedin accordance with published specifications and free from d

Page 30 - Figure 12 P1 Short Connector

IIIState Law: Some states do not allow the exclusion or limitation of implied warranties or liability forincidental or consequential damages, so t

Page 31 - User's Manual

IVSAFETY PAGEREAD FIRST• READ this user's manual before using this user system interface cable.• KEEP the user's manual handy for future ref

Page 32

VWARNINGObserve the precautions listed below. Failure to do sowill result in a FIRE HAZARD and will damage the usersystem and the emulator product or

Commentaires sur ces manuels