Chapter 3. Setting Up
With this product, it is necessary to set the following according to your target system.
Setting switches
Mounting the A-D conversion bypass capacitor
3.1 Switch Settings
It is necessary to set the switches of the M37906T-PRB for debugging according to the target system.
Figure 3.1 shows the positions of the switches of the M37906T-PRB, and Table 3.1 shows the switch
settings.
Figure 3.1 Positions of the switches and their factory-settings
Table 3.1 Switch settings of M37906T-PRB
Function Switch settingSwitch No.
X
OUT
output
selected
JP1
PLL filter
circuit
selected
JP2
When using the PLL filter circuit on
the target system or not using the
PLL function (Factory-setting)
When using the PLL filter circuit on
the pod probe
Does not output X
OUT
(Factory-setting)
Outputs XOUT
XOUT N.C XOUT N.C
U
T
U
T
CAUTION
Note on Switch Settings:
Always shut OFF power before setting switches. The power ON state could destroy
internal circuits.