6.4. Serial port
The microcontroller serial port SCIF0 can be used for RS232 communication. Please refer to Table 6-3 for the option links related with the
serial ports-
Description Function Fit for RS232 Remove to use
alternate function
TxD0 Serial Port Tx Pin R103 R103
RxD0 Serial Port Rx Pin R98 R98
Table 6-3 Serial Option Links
The board is designed to accept a straight through RS232 cable.
6.5. Debug LCD Module
The LCD module supplied with the RSK can be connected to the connector ‘LCD’ for use with the tutorial code. Any module that conforms
to the pin connections and has a KS0066u compatible controller can be used. The LCD module uses a 4bit interface to reduce the pin
allocation. No contrast control is provided; this must be set on the display module.
The module supplied with the CPU board only supports 5V operation.
Table 6-4 shows the pin allocation and signal names used on this connector.
LCD
Pin Circuit Net Name Device
Pin
Pin Circuit Net Name Device
Pin
1 Ground - 2 5V Only -
3 No Connection - 4 DLCDRS 138
5 R/W (Wired to Write only) - 6 DLCDE 148
7 No Connection - 8 No connection -
9 No Connection - 10 No connection -
11 DLCD4 140 12 DLCD5 136
13 DLCD6 135 14 DLCD7 134
Table 6-4 Debug LCD Module Connections
6.6. RCAN
Two RCAN ports are available on this board. The SH7203 on-chip RCAN module offers a flexible and sophisticated way to organise and
control CAN frames, providing the compliance to CAN2.0B Active and ISO-11898-1.
Table 6-5 details the CAN connectors available on
this RSK+ board -