104
Table 5.5 BREAKCONDITION_SET Command Parameters
Parameter Type Description
<address> Numerical value,
character string
Numerical value or symbol representing an address
bus value
<addrcycle> Keyword Address bus access conditions
pcafter: The address bus is targeted during instruction
fetch cycles. Breaks after the instruction at the
address set by the <address> parameter is executed.
When <addrcycle> is omitted, the address in the
program fetch cycles, and the address bus during data
access cycles are targeted.
<maskdata> Keyword Address bus mask conditions
Conditions are satisfied regardless of the values of
masked bits. Set a radix H' or B' and set * in the bit to
be masked.
<data> Numerical value Data bus value
<size> Keyword Sets the access conditions of the data bus. When
<size> is omitted, a byte size is specified.
Specify either of the following:
lbyte: lower 8 bits
hbyte: upper 8 bits
word: word size
<direction> Keyword Read/write conditions
Set either of the following keywords:
read: read cycles
write: write cycles
Note: The parameters for this command vary with the product. For the specifications of
each product, refer to the on-line help.