Renesas H8S/2378F Informations techniques Page 22

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 22
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 21
13
5. Precautions on Using Emulator
5.1 Precaution on Connecting the Emulator
When the emulator is connected, the [System Clock] dialog box may hide behind
the [Connecting] dialog box.
If the emulator is connected again after it has failed to be connected, the [Editor]
column will be disappeared from the source window of the HEW. In this case, exit
and restart the HEW and connect the emulator.
5.2 Break Condition Function
When Break Condition is set, no variable names or label names can be entered in
the [Break condition] dialog box, directly enter an address.
5.3 Precaution on Editing Register Values from the [IO] Window
No data will be written to memory when the values of a register before and after
editing are the same.
5.4 Precaution on Debugging
If a PC or SP value is illegally set (e.g., an odd value) and the user program is
executed, an error message such as ‘Program counter is odd’ may be displayed
twice.
5.5 Limitation during Writing to Flash Memory
Do not update the [Memory] or [Disassembly] window during writing to flash
memory. The HEW may not operate normally.
Vue de la page 21
1 2 ... 17 18 19 20 21 22

Commentaires sur ces manuels

Pas de commentaire