Renesas R8C/15 Informations techniques Page 26

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 42
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 25
Rev.2.00 Jan 30, 2006 Page 24 of 37
REJ03B0102-0200
R8C/14 Group, R8C/15 Group 5. Electrical Characteristics
NOTES:
1. This condition is not applicable when using with Vcc 1.0V.
2. When turning power on after the time to hold the external power below effective voltage (V
por1) exceeds10s, refer to Table
5.9 Reset Circuit Electrical Characteristics (When Not Using Voltage Monitor 1 Reset).
3. t
w(por2) is time to hold the external power below effective voltage (Vpor2).
NOTES:
1. When not using the voltage monitor 1 reset, use with Vcc 2.7V.
2. t
w(por1) is time to hold the external power below effective voltage (Vpor1).
Figure 5.3 Reset Circuit Electrical Characteristics
Table 5.8 Reset Circuit Electrical Characteristics (When Using Voltage Monitor 1 Reset
)
Symbol Parameter Condition Standard Unit
Min. Typ. Max.
V
por2 Power-On Reset Valid Voltage -20°C Topr < 85°C −−Vdet1 V
t
w(Vpor2-Vdet1) Supply Voltage Rising Time When Power-On Reset is
Deasserted
(1)
-20°C Topr < 85°C,
t
w(por2) 0s
(3)
−−100 ms
Table 5.9 Reset Circuit Electrical Characteristics (When Not Using Voltage Monitor 1 Reset)
Symbol Parameter Condition Standard Unit
Min. Typ. Max.
V
por1 Power-On Reset Valid Voltage -20°C Topr < 85°C −−0.1 V
t
w(Vpor1-Vdet1) Supply Voltage Rising Time When Power-On Reset is
Deasserted
0°C Topr 85°C,
t
w(por1) 10s
(2)
−−100 ms
t
w(Vpor1-Vdet1) Supply Voltage Rising Time When Power-On Reset is
Deasserted
-20°C Topr < 0°C,
t
w(por1) 30s
(2)
−−100 ms
t
w(Vpor1-Vdet1) Supply Voltage Rising Time When Power-On Reset is
Deasserted
-20°C Topr < 0°C,
t
w(por1) 10s
(2)
−− 1ms
t
w(Vpor1-Vdet1) Supply Voltage Rising Time When Power-On Reset is
Deasserted
0°C Topr 85°C,
t
w(por1) 1s
(2)
−−0.5 ms
NOTES:
1. Hold the voltage of the microcomputer operation voltage range (Vccmin or above) within sampling time.
2. A sampling clock can be selected. Refer to 6. Voltage Detection Circuit of Hardware Manual for details.
3. V
det1 indicates the voltage detection level of the voltage detection 1 circuit. Refer to 6. Voltage Detection Circuit of
Hardware Manual for details.
V
det1
(3)
Vpor1
Internal Reset
Signal
(“L” Valid)
t
w(por1)
tw(Vpor1–Vdet1)
Sampling Time
(1, 2)
Vdet1
(3)
1
f
RING-S
× 32
1
f
RING-S
× 32
Vpor2
Vccmin
tw(por2) tw(Vpor2–Vdet1)
Vue de la page 25