4. Enter debug mode.
This command resets the CPU and enters debug mode. After this command is executed it is possible
to access memory and registers.
5. Configure chip according application.
Before loading binary data into the processor memory, the memory should be made writable for the
debugger. Therefore processor configuration registers have to be set e.g. chip select register.
6. Load the program.
The format of the Data.LOAD command depends on the file format generated by the compiler. Refer
to “Supported Compilers” to find the command, that is necessary for your compiler. It is
recommended to use the option/verify that verifies all written data. This test discovers a problem with
the electrical connection, wrong chip configurations or linker command file settings.
For a detailed description of the Data.LOAD command and all available options see “Data” in
”General Commands Reference Guide D” (general_ref_d.pdf).
SYStem.Up
Data.LOAD.SR program.abs /verify ; SR specifies the format,
; program.abs is the file name