Rev.1.00 2003.05.08
page 12 of 23
M65881AFP
13. Power sequences
System power-on sequencing * Refer to following figure.
X
X
X
X
X
Power(Vddxxx, HPVddxxx,
XVdd, XOVdd, DVdd, BFVdd)
Master clock
(XfsoIN,XfsiIN)
INIT
SCDT
SCSHIFT
SCLATCH
Over 5msec(*1)
Over 0sec(*2)
Over 2/fso(*3)
Power ON
Power OFF
*1 After a power supply and Master clock become to stable, INIT pin must be "L" over 5msec.
*2 Data transfer is possible right after INIT release.
*3 Until SCLATCH is operated, a period over 2/fso ( fso=48kHz, over 42µsec ) is necessary after INIT release.