7 Windows/Dialogs
7.10.9.5 Measure the execution time of the specified function (2)
Measure the execution time of the specified function.
In this mode, the function address range is automatically registered to the measurement start event.
The measurement result does not contain the execution time of other function called within the
specified function.
Specify the following in the Measurement Condition Designation dialog.
ATTENTION
When the target function calls the other functions, the first measurement finishes at the first calling
the other function, and the second measurement begins at the returning to the target function from
the first one.