Figure 2 Connecting User System Interface Cable to Emulator Station 4
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER S
6 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an TFP-120 package on the u
Figure 4 Connecting User System Interface Cable to User System 7
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable bodyCable headRemove jigPush the remove jigRemovingUser systemFigure 5
2.3 Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. Figure 7 Dime
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head
12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided f
Figure 9 Installing MCU to User System 13
Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang
Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2328 series, turn on the emulator according to the procedures described
Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable
H8S/2328 Series TFP-120User System Interface Cable (HS2328ECN61H) for E6000 EmulatorUser’s ManualUser’s ManualRev.2.0 2003.04
Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intel
i Preface Thank you for purchasing this user system interface cable (HS2328ECN61H) for the Renesas’s original microcomputer H8S/2328 series. The HS23
ii Contents Section 1 Configuration...1 Section 2 Connection P
Section 1 Configuration CAUTION Use an IC149-120-043-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd) for the TFP-120 package IC
2 Table 1 lists the HS2328ECN61H components. Please make sure you have all of these components when unpacking. Table 1 HS2328ECN61H Components No.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. F