Section 2 User System Interface
All user system interface signals are directly connected to the MCU in the E6000 with no buffering
except for those listed below which are connected to the MCU through control circuits:
NMI
RES
MD3, MD2, MD1, MD0
EXTAL
HSTBY
WDTOVF
2.1 Signal Protection
All user system interface signals are protected from over- or under-voltage by use of diode arrays
except for the AVcc.
Pull-up resistors are connected to the port signals except for the analog port signals.
The Vcc pins (except for the AVcc pin) at the head of the user system interface cable are
connected together. The E6000 monitors this and determines whether the user system is
connected.
2.2 User System Interface Circuits
The interface circuit between the MCU in the E6000 and the user system has a signal delay of
about 8 ns due to the user system interface cable and it includes pull-up resistors. Therefore, high-
impedance signals will be pulled up to the high level. When connecting the E6000 to a user
system, adjust the user system hardware to compensate for propagation delays.