Serial Flash Programmer Operation Manual S550-SFWv3 Sunny Giken Inc.
● Top Side View Connector Function SERIAL Cable connector for connecting the target. ● Bottom Side View Connector Function US
④ Complete Downloading ・ When the dialog “DownLoad Complete” appears, downloading is complete. ・ In “Multi Data Mode”, the data with the smallest
8.1.3. Programming ① Download ・ Download programming data to S550-SFWv3. *The programming data shall be downloaded to the main unit for stand-alo
8.2. Stand-alone Initialization You can initialize data that is stored in the S550-SFWv3 internal memory on unit basis for security purposes. The
8.3. Center Display Modes 8.3.1. Mode Transition Diagram Following illustrates mode transitions of S550-SFWv3 center display. (Single
(Multi Data Mode) FUNCFUNCSTART STARTSTARTSTARTSTARTSTART "P.3"."P.4&quo
8.3.2. Normal Display Mode This is the screen when power is turned on. The S550-SFWv3 displays the checksum lower 1 byte of the data stored in
8.3.4. Programming Information Display The S550-SFWv3 displays the programming information of the data stored in the internal memory of the main
8.3.6. Data Switch Display With the “Multi Data Mode”, you can select programming data on S550-SFWv3. Following shows how to select the data. *Whe
9. Messages and Warnings 9.1. Message Dialogs Display Contents S550-SFWv3 already started. Displayed when trying to start up the control soft
Display Contents Some Maintenance setting items has been edited. Do you want to replace the existing items? Confirmation whether to valida
2.6. Connector Pins Specifications ・ Connector Pins (S550-SFWv3 Main unit) ・ Model : XG4C-1434 OMRON Corporation ・ Pin Assignment (S550-
Display Contents Initialize... Displayed while initializing. Finish Displayed when programming has been complete. Initialize Stop... Displayed w
9.2. LED Status List Operation Condition LED Status No settings made by PC After “POWER” is lighted, “PASS”, “ID ERR”, and “FAIL” will blink o
Operation Condition LED Status Firmware updating “PASS”,“ID ERR” and “FAIL” will all be lighted. Firmware updating complete “PASS”, “ID ERR” and
9.4. List of Error Information on Center Display Center display status Descriptions "0","0" Programming is canceled after S
9.6. Initialized Settings (factory setting) List Items Default status (Factory setting) Programming data Data set in the device setting screen
10. Troubleshooting 10.1. Mode entry error occurs when programming The mode entry error occurs while preparing for programming. Following shows
10.6. Memory error occurs when programming Memory error occurs when the S550-SFWv3 main unit ROM is damaged. Following shows how to resolve. ① D
Version Revised contents Revised date Rev.A First edition 2010/03/29 Rev.B Changes of the whole ・The description has been changed from the “R
Rev.C 2.3. System Requirements ・Windows 7(32bit) has been added to OS. 5.1. Installing USB driver ・"5.1.1 Windows 7(32bit)" has been added
Rev.G 2.2.Function Specifications ・The Operation Mode has been changed. 2.7. Target Connecting Cable ・The explanation of Target Connecting Cable has
2.7. Target Connecting Cable 2.7.1. 14 – 14 Standard Cable The attached connecting cable is a straight cable. In case the connector specificat
Overseas Standard ・CE Mark Obtained (EMI:EN55011 Group1 ClassA ,EMS:EN61000-6-2) ・FCC Compliance This device complies with part 15 of the FCC Rul
2.7.4. 14 – 14 Custom2 Cable(model: S550-SFW-CB2) The optional connecting cable converts 14pin connector to 14pin(Applicable for RX Family(except
3. Circuitry Examples Refer to the file “S550-SFWv3 Examples of circuit for serial programming”in the enclosed CD-ROM. 4. Connections S550-SFW
4.2. Connection for Stand-alone Programming / Stand-alone Initializing The connection when you program from the lone S550-SFWv3 to the target (st
4.3. Connection for Remote Programming The connection when you program remotely to the target from the PC using the control software though S550-
(When supplying voltage to the target board from S550-SFWv3 – Single CH Mode) Target connection cable Your tar
(When supplying voltage to the target board using an external power supply - Multi CH Mode) S550-SFWv3 USB cable SFWv3 controlsoftware PC (OS:
(When supplying voltage to the target board from S550-SFWv3 - Multi CH Mode) USB cable SFWv3 controlsoftware
Serial Flash Programmer S550-SFWv3 The contents of this manual may be revised without notice. We, Sunny Giken Inc. shall not be responsible for
5. Setting Up 5.1. Installing USB driver When S550-SFWv3 is connected to a PC by USB, Windows automatically detects a new hardware and creates
iii) The following Dialog will be displayed. Press "Finish" button. Serial Flash Programmer[S550-SFWv3] Operat
5.1.2. Windows 7(64bit) i) Execute "dpinst.exe" of the “Driver64” folder. "Device Driver Installation Wizard" Dialog will be
iii) The USB driver package is being installed. Please wait for a moment. iv) The following Dialog will be displayed. Pre
5.1.3. Windows Vista i) “Found New Hardware” dialog will be displayed. Select “Locate and install driver software”. ii) Sele
iii) The driver files will be automatically copied and installation will be completed. Serial Flash Programmer[S550-SFWv3
5.1.4. Windows XP i) “Found New Hardware Wizard” dialog will be displayed. Select “Install from a list or specific location” and press [Next].
iii) The driver files will be automatically copied and installation will be completed. Serial Flash Programmer[S550-SFWv3] Operation Manual 26
5.1.5. Windows 2000 i) ”Found New Hardware Wizard” dialog will be displayed. Press [Next]. ii) Select ”Search for a suita
iii) Select “Specify a location” and press [Next]. iv) Specify “USBDrv” folder in the attached CD-ROM for the area to copy fil
Table of Contents 1. Outline...
vi) The driver files will be automatically copied and installation will be completed. Serial Flash Programmer[S550-SFWv3] Operation
5.2. Installing Control Software Using the attached CD-ROM, execute “Setup.exe” in “Software” folder. The following is the software installatio
iii) Files are automatically copied and installation will be completed. 5.3. Uninstalling Control Software From the Con
6. Control Software 6.1. Main Screen 6.1.1. Main Screen (Single Data Mode, or Single CH Mode) (Multi Data Mode)
(Multi CH Mode) For “Multi CH Mode”, see “6.3.1 Maintenance Initial Setting Screen”. Serial Flash Programmer[S550-SFWv3] O
<Information section> Items Descriptions Shows MCU manufacture. Shows MCU series. Shows MCU model. * The device displayed (ECC) after the
<Project menu> Items Descriptions “New”: Discards the current settings and starts new setting. “Open...”: Opens a project file. “Save As
6.1.2. About Screen (Single CH Mode) (Multi CH Mode) Items Descriptions Shows the control software version. Sh
6.1.3. Initialize Setting Screen The following screen is displayed only in the "Multi CH Mode". <<S550-
6.1.4. UpLoad Setting Screen The following screen is displayed only in the "Multi CH Mode". <<S550-SFWv3
7.1.1.1. Process Flow up to Programming... 59 7.1.1.2.
6.1.5. DownLoad Setting Screen The following screen is displayed only in the "Multi CH Mode". <<S550-SF
6.1.6. Program Setting Screen The following screen is displayed only in the "Multi CH Mode". <<S550-SFW
6.2. Device Setting Screen 6.2.1. Device Setting Screen <<Device section>> Items Descriptions Select MC
Items Descriptions Opens the clock frequency setting screen. (See “6.2.3 Clock Frequency Setting Screen”.) Shows main clock frequency. Shows per
<<Main menu>> Items Descriptions “Main”: Moves to Main screen. *After a confirmation message, setting contents will be discarded.
6.2.2. Device Detail Display Screen Items Descriptions Shows MCU model. Shows the minimum value of the ROM block addr
6.2.4. User Program File Load Screen Select a user program file to load and press “Open”. When the file is loaded successfully,
6.2.5. User Program Edit Screen Items Descriptions Shows MCU model. Shows the user’s program name with the path
Items Descriptions Searches user’s program data or address. (See “6.2.6 User’s Program Data Search Screen”.) Fills the selected area with the id
6.2.8. User’s Program Data Saving Screen Items Descriptions Selects all area for saving. Selects address range for savi
1. Outline 1.1. Precautions Thank you for purchasing our product. Please read this operation manual carefully to understand the functions of t
6.2.10. ROM Area Block Information Setting Screen Items Descriptions Selects “Keep Device Lock Bits” for lock bit process
6.2.11. ROM Protection Setting Screen (R32C/100 Series) Items Descriptions Sets whether to execute BP Bit_Program for all BP0 and BP1
(78K,RL78 Family) Items Description Sets whether to execute Flash Option. Execution of the chip erase command is disabled. Execution of the
6.2.12. Input Vcc Setting Screen Items Descriptions Input vcc. Reflects the setting content and closes the screen. Discards the setting co
<Initial Setting section> Items Descriptions Enables saving the action log (operation execution log). Set saving destination for the ac
6.3.2. Password Setting Screen Items Descriptions Sets a password. Maximum of 8 single byte characters can be set. *The password is ref
6.3.3. Execution Operation Log Display Screen <Logging section> Items Descriptions Select a log file to displa
6.4. Execution Screen 6.4.1. Execution Screen (Single CH Mode) Serial Flash Programmer[S550-SFWv3] Operation Manual
(Multi CH Mode) <<Information section>> Items Descriptions Shows MCU manufacturer. Shows MCU series
<<Pass/Fail Counter section>> Items Descriptions Shows the number of successful programming. Shows the number of programming errors
1.2. System Configuration The entire system configuration of the Serial Flash Programmer S550-SFWv3 is illustrated below.
7. Remote Mode 7.1. Single CH Mode 7.1.1. Remote Programming 7.1.1.1. Process Flow up to Programming The following section describes the ope
7.1.1.2. Maintenance Settings With the control software, you can change S550-SFWv3 main unit setting. The following illustrates an example of th
② Save execution operation log ・ Check the “Ena” check box to save execution operation log. ・ To select the saving destination for execution op
③ Save device setting file ・ To select the saving destination for the device setting file, click the “Save Directory” button and select the des
④ Set password ・ Check the “Enable” check box to set a password to S550-SFWv3 main unit. Uploading data to program will require the password when
⑤ Select extended operation mode ・ Check the “Enable Expansion Action Mode” check box to select the extended operation mode. Standard operation m
⑥ Select power saving mode ・ Check the “Enable Power Save Mode” check box to set power saving mode of the S550-SFWv3 main unit. *When power sa
⑦ Select mute ・ Check the “Mute” check box to mute S550-SFWv3 main unit’s buzzer sound. Serial Flash Programmer[S550-SFWv
⑧ Select “Multi Data Mode” ・ Check the “Enable Multi Data Mode” check box to set the “Multi Data Mode”. ・ Maximum of 4 data can be set or do
⑨ Select “Multi CH Mode” ・ Check the “Enable Multi CH Mode” check box to set the "Multi CH Mode". Please see "7.2.1.2 Maintenanc
2. Specifications 2.1. Specifications Operating Environment Ambient temperature : 0°C to 40°C Humidity: below 80% (non-condensing) Storage E
7.1.1.3. Data Settings With the control software, you can set the data to program. The following illustrates an example of the programming data
③ Select a device ・ Select the target device from “Maker” list, “MCU” list and “Type” list. ④ Select communication m
⑤ Select clock frequency ・ Click “Set Freq” button, input the clock frequency of the target board and select the clock multiplying rate from th
⑦ Edit data ・ Data is editable by clicking the “Edit” button, “Set ID” button, “Set Block” button” and/or “Set Protect” button. *For Editing, see
⑨ Confirm data ・ Confirm whether programming data is correct. ・ After checking, click the “Set” button and move to the main screen.
⑩ Save project (device setting) file (Single Data Mode) ・ You can save the contents set in the device setting screen and maintenance screen as a
⑪ Load a project file ・ Load the project file (device setting information and maintenance screen information) saved with the operation10 descri
⑫ Discard device setting (Single Data Mode) ・ You can discard the contents set in the device setting screen. ・ Select “New” from the “Project” m
⑬ Copy device setting (Only in the “Multi Data Mode”) ・ Select data of the copy origin and click the “Copy” button and move to the “Copy Informat
③ Start downloading ・ Click the “DownLoad” button. ・ The progress bar will show the downloading progress status. ・ Click “Cancel” to cancel
2.4. Programmable Device The Renesas built-in Flash Memory Microcomputers are the programmable devices. Some devices are under evaluation or no
④ Downloading complete ・ Downloading is complete when the execution screen appears. ⑤ Start programming ・ Click t
⑥ Programming complete ・ When the “Result” area is yellow-green, programming is complete. When the area is in red, error occurred in programming.
7.1.2. Uploading You can upload the programming data stored in S550-SFWv3 to the control software (Upload). The following procedures show how to u
④ Start Uploading ・ The progress bar will show the uploading progress status. ・ Click “Cancel” to cancel uploading in midstream. *If
(Multi Data Mode) e.g.) Uploading 4th data stored in S550-SFWv3 to the 3rd data (i) Select uploading destination data number (1 through 4). Cl
7.1.3. Initialization You can initialize data that is stored in the S550-SFWv3 internal memory on unit basis for security purposes. The followings
7.2. Multi CH Mode 7.2.1. Remote Programming 7.2.1.1. Process Flow up to Programming The following section describes the operations from setti
7.2.1.2. Maintenance Settings With the control software, you can change S550-SFWv3 main unit setting. The following illustrates an example of th
② Select Multi CH Mode ・ Check the “Enable Multi CH Mode” check box to set the "Multi CH Mode". ・ It is possible to Initialize/Upload
③ Start downloading ・ Click the “Program” button. ・ Select channels and click "OK" button. * In the "DownLoad" list, the it
2.5. S550-SFWv3 External Appearance The external appearance of S550-SFWv3 is shown below with descriptions of switches, LEDs, connectors and acc
*If the data in the S550-SFWv3 main unit and the data in the control software are identical, downloading will not be processed with the message “It
④ Downloading complete ・ Downloading is complete when the execution screen appears. ⑤ Start programming ・ Click t
⑥ Programming complete ・ When the “Result” area is yellow-green, programming is complete. When the area is in red, error occurred in programming.
7.2.2. Uploading You can upload the programming data stored in S550-SFWv3 to the control software (Upload). The following procedures show how to u
④ Start Uploading ・ The progress bar will show the uploading progress status. ・ Click “Cancel” to cancel uploading in midstream. *If
7.2.3. Initialization You can initialize data that is stored in the S550-SFWv3 internal memory on unit basis for security purposes. The followings
④ Start Initializing ・ Click the “Initialize” button and the confirmation dialog asking, “Do you want to initialize?” Click the “OK” button to sta
8. Stand-alone Mode 8.1. Stand-alone Programming 8.1.1. Process Flow up to Programming The following section describes the operations from se
8.1.2. Downloading You can store the data set with the control software in the S550-SFWv3 main unit (Download). The following procedure shows how
③ Start Downloading ・ Click the “DownLoad” button. ・ The progress bar will show the downloading progress status. ・ Click “Cancel” to cancel
Commentaires sur ces manuels