Q.
Will the cyclic handler begin processing in the interrupt disable state? Or does it start processing in the interrupt enable state?
A.
The cyclic handler is enabled by an interrupt which has an interrupt level higher than that of the MR308 system clock interrupt.
(Starts at I flag = 1, IPL = system clock Interrupt Priority Level.)