Renesas Technology, Tools FAQs
Last Updated: November 5, 2003
Document Number: 03092204_e
Q.
How should the emulator and target system be connected for M38C8 debug?
A.
There is no board available for converting the M38C89RLFS (PGA package) as is to the target system. When connecting the
emulator and target system, we suggest you use the universal section on the M38C89T-ADF temporary target board. The connection
method is as follows:
(1)Connect the pod to M3T-28DP-WS (bundled with emulation pod), then M3T-28DP-WS to M38C89T-ADF.
(2)Mount M38C89RLFS on M38C89T-ADF.
(3)Connect the user target system to the universal section (through-hole for 2.54 pitch connecter) on M38C89T-ADF. Refer to the
M38C89T-ADF Users Manual for pin configuration.