iSYSTEM, September 2014 16/23
Before the program is set to run or while it is running already, activate the trace recording by the
‘Trace begin’ tool bar or the CTRL+B shortcut key. The trace stops recording when the program
execution is stopped. After the trace stops recording, the collected information is analyzed and
displayed.
Select a start ‘Immediately’ or ‘On Triggerwhen the trace should record only until the trace buffer
gets full.
Example 2: Trace triggers when function Type_Simple() is called and program execution is recorded
around the trigger event.
Create a new Trace Trigger in the Analyzer window and open the trigger configuration dialog. First,
select ‘Enabled’ in the Trigger combo box on top of the dialog, next set Execution Watchpoint 1 for the
trigger condition and then enter Type_Simple address in the corresponding address field.
Leave the ‘Qualifier‘ pane at default setting, which records program flow only.