M30870T-EPB User’s Manual 2. Setup
R20UT0209EJ0400 Rev.4.00 Page 45 of 106
Aug 16, 2012
2.10.2 Selecting Clock Supply
There are two ways to sup
ply a clock to the MCU, using the oscillator circuit of the emulator or using the oscillator circuit on
the user system. Table 2.5 lists the factory-settings of each clock supply.
Table 2.5 Clock supply to the MCU and default settings
Clock Display of emulator debugger Description Default setting
Internal
Internal oscillator circuit
(OSC-3 or OSC-2)
Yes
External Oscillator of user system -
Main X
IN
-X
OUT
Generated
Internal generator circuit
(1.0 to 32.0 MHz)
-
Internal
Internal oscillator circuit
(32.768 kHz)
-
Sub X
CIN
-X
COUT
External Oscillator of user system Yes
Notes on Changing the Clock Supply:
The clock supply can be set by the Init dialog box when starting up the emulator debugger or inputting
CLK command on the script window.
For X
CIN
-XC
OUT
, it is necessary to set switches in the emulator. For details, refer to "2.10.1 Setting
Switches of Emulation Probe" (page 40).
(1) Using an Internal Oscillator Circuit Board
1) Kinds of Oscillator Circuit Boards
The PC7501 comes with an oscillator circuit board OSC-3 (30 MHz). And an oscillator circuit board OSC-3 (32 MHz)
and an oscillator circuit board OSC-2 (bare board) are included with this product. If you use the internal oscillator
circuit board OSC-3 (32 MHz) or OSC-2 of the PC7501 as a main clock, choose "Internal" in the emulator debugger
after replacing oscillator circuit boards to change a clock supplied to an MCU.
Commentaires sur ces manuels