49
14. Reset Input
During execution of the user program, the emulator may not operate correctly if a contention
occurs between the following operations for the emulator and the reset input to the target
device:
Setting an Event Condition
Setting an internal trace
Displaying the content acquired by an internal trace
Reading or writing of a memory
Note that those operations should not contend with the reset input to the target device.
15. Contention between the Change of the FRQCR Register and the Debugging Functions
The following notes are required for the user program for changing the multiplication rate of
PLL circuit 1 to change the frequency:
Avoid contention between the change of the FRQCR register in the user program and the
memory access from the [Memory] window, etc.
When the automatic updating function is used in the [Monitor] window or [Watch] window,
generate and set a break of Event Condition for an instruction immediately before changing the
FRQCR register. Contention will be avoided by generating a break and executing the user
program again.
For the change of the multiplication rate of PLL circuit 1 and the FRQCR register, refer to the
hardware manual for the MCU.