52
The [Event Condition 11] dialog box is used to specify the count of [Event Condition 1] and
becomes a reset point when the sequential condition is specified.
Sequential Setting: Use the [Combination action(Sequential or PtoP)] dialog box to specify the
sequential condition and the start or end of performance measurement.
Table 3.10 Conditions to Be Set
Classification Item Description
[Ch1, 2, 3] list box Sets the sequential condition and the start or end of performance
measurement using Event Conditions 1 to 3 and 11.
Don’t care Sets no sequential condition or the start or end of
performance measurement.
Break: Ch3-2-1 Breaks when a condition is satisfied in the order of
Event Condition 3, 2, 1.
Break: Ch3-2-1,
Reset point
Breaks when a condition is satisfied in the order of
Event Condition 3, 2, 1.
Enables the reset point of Event Condition 11.
Break: Ch2-1 Breaks when a condition is satisfied in the order of
Event Condition 2, 1.
Break: Ch2-1,
Reset point
Breaks when a condition is satisfied in the order of
Event Condition 2, 1.
Enables the reset point.
I-Trace stop: Ch3-2-1 Halts acquisition of an internal trace when a
condition is satisfied in the order of Event Condition
3, 2, 1.
I-Trace stop: Ch3-2-1,
Reset point
Halts acquisition of an internal trace when a
condition is satisfied in the order of Event Condition
3, 2, 1.
Enables the reset point.
I-Trace stop: Ch2-1 Halts acquisition of an internal trace when a
condition is satisfied in the order of Event Condition
2, 1.
I-Trace stop: Ch2-1,
Reset point
Halts acquisition of an internal trace when a
condition is satisfied in the order of Event Condition
2, 1.
Enables the reset point.