40
3.7.2 Setting an On-Chip Breakpoint
Use the [On Chip] sheet on the [Event] window to display, change, or add settings for on-chip breakpoints.
Select [Add...] or [Edit…] from the popup menu displayed on the [On Chip] sheet. The [Breakpoint Properties]
dialog box (the [On Chip Break] page) will appear.
Figure 3.22 [Breakpoint Properties] Dialog Box ([On Chip Break] Page)
[Sequential Break]: Use this item to specify a sequential break consisted of on-chip breakpoints. A
sequential break allows breaking the program when the conditions of several channels
are satisfied sequentially. Two to four points can be selected for this function. The
conditions are satisfied from 1 to 4, in order. Check a box to use the sequential break
function (select 3 to use two points, 2 to use three points, and 1 to use four points).
[Address Range Break]: Selecting a combination of channels specifies the break range. Select either of the
followings:
4-3: Channels 4 and 3 are used to specify the break range.
2-1: Channels 2 and 1 are used to specify the break range.
[Run time count between trigger outputs]:
Measures the time between two points by using channels 3 and 4. After channel 3 has
been satisfied, the time is measured when channel 4 is satisfied. The result is
displayed in [RunTime Count] on the [Platform] sheet of the [Status] window.