55
(3) [Trace Acquisition Condition Channel n] dialog box
Use this dialog box to set pass points and a reset point for a sequential trace stop, and conditions in the address
range trace, address range conditional trace, conditional trace, Point to Point trace, execution time measurement,
and a trigger output.
Figure 3.29 [Trace Acquisition Condition Channel n] Dialog Box
The [Trace Acquisition Condition Channel n] dialog box has pages [Action], [Address], [Data], [Bus/Area],
[Probe], [Interrupt], [Count], and [Delay]. The user can make more complex settings by a combination of
conditions provided on these pages.
[Action]
[After Condition Match]: Selects an action to take when a condition is satisfied.
[Trace Stop]: Selects a trace stop.
[Address Range Trace]: Selects an address range trace. Selecting this option and checking
[Combination with the next channel] allows an address range
conditional trace.
[Acquisition Condition]: Selects a conditional trace.
[None]: Select this option if you do not want to take any of the actions listed
above. This is useful for a trigger output or execution time
measurement.
[Address]: Sets the start and end addresses of the range in the address range trace,
address range conditional trace, or Point to Point trace.